Bellows Sealed Rotary Feedthroughs
Precision Rotary Feedthroughs
Accu-Glass Products high-torque HTR series bellows sealed rotary feedthroughs are designed to operate at temperatures as high as 250°C and rotational torque up to 250 in-oz.
They are constructed of black-anodized aluminum and stainless steel, where only stainless steel surfaces are exposed to the vacuum environment. In vacuum bearings are dry-film lubricated with tungsten-disulfide, while air side bearings are lubricated with high-temperature Krytox® lubricant. The rotation shaft is sealed with an AM-350 edge-welded bellows.
Standard rotary feedthroughs are fitted with a 1.65 diameter manual actuator, which can be fitted with an optional three-spoke Speed-Handle for faster actuation. Factory-converted motorized solutions are also available on request. Our motor options include a reversible constant speed AC motor, two DC stepper motors, for medium and high toque applications respectively, and a 90° pneumatic actuator.
Manual feedthrough rotation can be monitored via a 360° / 5° increment laser-etched scale found on the manual actuator knob. Rotary feedthroughs are available on Conflat® compatible CF style metal seal or ISO-KF elastomer seal flanges.
Features
- Precision bearings — no bushings
- Improved shaft coupling design for high torque, rated to 250 in-oz
- High temperature rated to 250°C
- UHV compatible construction
- Conflat® and ISO compatible mounts
- Edge-welded metal bellows seal
- Manual actuators
- Continuous 360° rotary motion
- Rotary travel position lock
- Optional AC or DC motor actuators
- Custom solutions on request
Specifications
Material | |
Body, Stainless Steel | 304 |
Housing, Anodized Aluminum | 2011 |
Bellows, Edge-Welded | AM-350 |
Vacuum Range | |
UHV, Ultrahigh vacuum | 1x10E-10 Torr |
HV, High vacuum | 1x10E-8 Torr |
Temperature Range 1 | |
Feedthrough | 250°C |
Flange, Conflat® | 450°C |
Flange, ISO | 150°C |
Load | |
Axial, Maximum | 6 lb |
Lateral, Maximum 2 | 10 lb |
Resolution 3 | |
Rotary Scale | 5° |
Motorization Options 4 | |
DC Step Motor | Option-11 |
DC Step Motor HT | Option-12 |
AC Geared Motor | Option-21 |
Pneumatic, 90° | Option-31 |
Notes |
- Overall assembly ratings must be adjusted to that of its lowest rated component. For cryogenic service, the lowest recommended temperature is -80°C
- With load positioned 2-Inches from flange sealing face
- See detailed motor specifications for various Step motor resolutions
- To see detailed specifications for each motor option, click the specific 'motorization option tile' above.