SMA - Single Ended, Grounded Shield Feedthrough on a NW16 KF Flange
SMA - Single Ended, Grounded Shield Coaxial Feedthrough on a NW16 KF Flange.
SMA - Single Ended, Grounded Shield Coaxial Feedthrough on a NW16 KF Flange.
SMA - Single Ended, Grounded Shield Coaxial Feedthrough on a NW40 KF Flange.
SMA - Single Ended, Grounded Shield Coaxial Feedthrough x 2 on a NW40 KF Flange.
SMA - Single Ended, Grounded Shield Coaxial Feedthrough x 3 on a NW40 KF Flange.
SMA - Single Ended, Grounded Shield Coaxial Feedthrough x 4 on a NW50 KF Flange.
SMA - Single Ended, Grounded Shield Coaxial Feedthrough x 5 on a NW50 KF Flange.
SMA - Double Ended, Grounded Shield Coaxial Feedthrough on a NW16 KF Flange.
SMA - Double Ended, Grounded Shield Coaxial Feedthrough on a NW40 KF Flange.
SMA - Double Ended, Grounded Shield Coaxial Feedthrough x 2 on a NW50 KF Flange.
The 'Subminiature Type-A' coaxial connector, referred to as the SMA coaxial interface, is commonly used in conjunction with high-frequency, low noise 50-ohm instrumentation signal lines. SMA coaxial feedthroughs are constructed in both grounded and floating shield configurations. Floating shield types provide two concentric conductor paths: an outer metal conductor tube (shield) concentric with, and enclosing, a cylindrical center conductor pin. Both paths are electrically isolated from each other and a mounting flange. Grounded shield SMAs provide only one path that's electrically isolated from the flange, where grounded shield and flange are electrically common.
Vacuum side of single-ended grounded and floating SMA feedthroughs have a 0.094 inch (2.4-mm) diameter conductor pin that mates with grounded or floating AccuFast™ connectors. Vacuum compatible cable assemblies are fitted with Kapton® insulated 26 AWG, 50-ohm coaxial cable, with either AccuFast™ connectors or gold-plated SMA connectors.
Warning — SMAs, with .250-36 thread and .035/.037 pin diameter, are often mistaken for Microdot S-93, connectors with .250-32 threads and .030/.033 pins. To avoid possible damage to one or both connector interfaces, these connectors should never be cross-mated. Compare Microdot ® and SMA differences below...


| Electrical | |
| Voltage 1, Maximum | |
| Grounded Shield | 700 VDC |
| Floating Shield | 700 VDC |
| Current, Max @ 20°C | 1 A |
| Impedance2, Nominal | 50 Ohms |
| Frequency2, Nominal | 6 GHz |
| Material | |
| Shell | 304 Ss |
| Pin / Conductor | 304 Ss |
| Insulation, Ceramic | Alumina |
| Connector, Vacuum 3 | |
| AccuFast™ | PEEK / Ss |
| SMA (Au plated) | PEEK / Brass |
| Connector, Air | Teflon® |
| Cable Insulation (Type F Film) | Kapton® |
| Vacuum Range | |
| UHV, Ultrahigh vacuum | 1x10E-10 Torr |
| HV, High vacuum | 1x10E-8 Torr |
| Temperature Range4 | |
| Feedthrough, Single Ended | 250°C |
| Flange, Conflat® | 450°C |
| Flange, ISO | 150°C |
| Connector / Cable, Air | 165°C |
| Connector / Cable, UHV | 250°C |
| Thermal Gradient, Maximum | 25°C/minute |
| Notes |